| Specification |
Details |
| Type |
Anchor / Dead End Clamp for ABC Cable |
| Application |
Used for terminating and anchoring LV aerial bundled cables (ABC) on poles or walls |
| System Voltage |
Up to 1.1 kV (Low Voltage Distribution System) |
| Cable Range |
Suitable for 2-core, 3-core, or 4-core ABC cables (16 mm² – 95 mm²) |
| Operation |
Mechanical tension type; no special tools required for installation |
| Installation |
Easy installation without cutting or stripping cable insulation |
| Mounting |
Pole-mounted or wall-mounted using hooks or brackets |
| Standards |
Conforms to NFC 33-042, IEC 61284, and relevant Indian standards |
| Design Type |
Wedge-type self-locking design with stainless steel bail |
-
| Specification |
Details |
| Type |
Mid Span Joint / Straight Joint Connector |
| Application |
Used for connecting or extending LV ABC (Aerial Bundled Cable) conductors without cutting insulation |
| System Voltage |
Up to 1.1 kV (Low Voltage Distribution System) |
| Cable Compatibility |
Suitable for 2-core, 3-core, or 4-core LV ABC cables (16 mm² – 150 mm²) |
| Operation |
Mechanical / shear-head bolt type; ensures reliable connection without crimping |
| Installation |
Quick and easy – no stripping of cable insulation required |
| Mounting |
Inline jointing of conductors at mid-span |
| Standards |
Conforms to NFC 33-020, IEC 61238, and IS: 13779 / IS: 5561 |
| Design Type |
Insulated, waterproof, and fully sealed joint for outdoor service |
-
| Specification |
Details |
| Type |
Insulation Piercing Connector (IPC) |
| Application |
Used for branching or tapping connections in LV Aerial Bundled Cable (ABC) systems without stripping insulation |
| System Voltage |
Up to 1.1 kV (Low Voltage Distribution Networks) |
| Cable Compatibility |
Main (Run): 16–95 mm², Tap: 16–95 mm² (as per image marking) |
| Operation |
Mechanical tightening with shear-head bolt ensuring perfect contact pressure |
| Installation |
Tool-operated, no stripping or pre-processing of cable insulation required |
| Mounting |
Suitable for overhead ABC systems and insulated copper/aluminum conductors |
| Standards |
Conforms to NFC 33-020, EN 50483-4, and IEC 61238 standards |
| Design Type |
Fully insulated, weatherproof, and UV-resistant clamp body |
-
| Specification |
Details |
| Type |
Suspension Clamp for LV ABC System |
| Application |
Used to suspend and support LV ABC (Aerial Bundled Cable) conductors on poles or walls at intermediate spans |
| System Voltage |
Up to 1.1 kV (Low Voltage Overhead Distribution Lines) |
| Cable Compatibility |
Suitable for 2-core, 3-core, or 4-core ABC cables (16 mm² – 95 mm²) |
| Installation |
Fixed on poles with a hook, bracket, or banding; tool-free mounting design |
| Operation |
Provides mechanical suspension without damaging the cable insulation |
| Mounting Orientation |
Vertical or horizontal pole mounting |
| Standards |
Conforms to NFC 33-040, EN 50483-3, IEC 61284, and relevant Indian Standards |
| Design Type |
Flexible swivel type allowing angular movement and vibration absorption |
-
| Specification |
Details |
| Type |
Outdoor, triple pole (3-phase), gang-operated Air Break (AB) Switch |
| Application |
Used for isolating or switching high-voltage power lines and equipment under off-load conditions |
| System Voltage |
11 kV, 22 kV, or 33 kV (3-phase, 50 Hz, solidly earthed neutral system) |
| Rated Voltage |
12 kV for 11kV system; 24 kV for 22kV system; 36 kV for 33kV system |
| Operation |
Manual operation through ground-level handle and GI pipe operating rod |
| Mounting |
Horizontal / Vertical mounting on pole or substation structure |
| Insulation Type |
Polymer / Porcelain post insulators (2 or 3 per phase) |
| Standard Compliance |
IEC 62271-103, IS: 9920 (Part I to IV), IS: 2544 |
| Design Type |
Tilting / Rotating gang-operated type with visible air gap |
-
| Specification |
Details |
| Type |
Copper Back Plate / Connector Plate |
| Application |
Used as a connecting terminal or mounting plate in transformers, switchgear, and electrical panels |
| Material |
High conductivity electrolytic copper (Cu-ETP / Cu 99.9%) |
| Mounting Type |
Bolt-on type for busbar, terminal, or bushing connections |
| System Voltage |
Suitable for up to 33 kV applications (depending on insulation and system design) |
| Operation |
Static mechanical and electrical connection component |
| Compatibility |
Fits transformer terminals, AB switch connectors, or heavy-duty earthing setups |
| Standards |
IS: 613, IS: 1897, IS: 1367, IEC 60439 |
| Design Type |
Flat plate with multiple precision-drilled holes for mechanical fastening |
-
| Specification |
Details |
| Type |
Brass Hex Nut and Bolt Set |
| Application |
Used in electrical fittings, switchgear, transformers, busbars, and general-purpose fastening |
| Material |
High-grade brass (CuZn39Pb3 / IS 319 Type I) |
| Thread Type |
Metric (MM) / UNC / UNF (as per requirement) |
| Operation |
Manual fastening using wrench or spanner |
| Mounting Type |
Through-hole, clamp, or plate mounting |
| Head Type |
Hexagonal head for easy grip and torque application |
| Standard Compliance |
IS 1367, IS 319, BS 4183, DIN 933/934 |
| Finish Type |
Natural brass, nickel-plated, or chrome-plated (optional) |
-
| Specification |
Details |
| Type |
GI (Galvanized Iron) Hex Nut and Bolt Set |
| Application |
Used in transmission towers, pole line hardware, substation structures, and general-purpose fastening |
| Material |
Mild Steel / Carbon Steel (as per IS:1367) |
| Surface Coating |
Hot Dip Galvanized (HDG) |
| Thread Type |
Metric (MM) / UNC / UNF (custom options available) |
| Operation |
Manual fastening using wrench or spanner |
| Mounting Type |
Through-hole, clamping, or structure-mounted |
| Head Type |
Hexagonal head for easy torque application |
| Standard Compliance |
IS 1367, IS 3757, IS 1363, DIN 933/934 |
| Finish Type |
Hot dip galvanized zinc coating (minimum 40–80 microns) |
-
| Specification |
Details |
| Type |
Aerial Bunched Cable (ABC) |
| Application |
Used for overhead power distribution in low and medium voltage networks |
| System Voltage |
LV: 1.1 kV / MV: 11 kV or 33 kV (as per configuration) |
| Conductor Material |
Aluminium (Stranded, compacted, circular) |
| Insulation Material |
XLPE (Cross-Linked Polyethylene) / HDPE (High-Density Polyethylene) |
| Core Configuration |
2 Core / 3 Core / 4 Core + 1 Neutral (Messenger Wire optional) |
| Messenger Wire (Optional) |
Insulated or bare aluminium alloy wire for mechanical support |
| Frequency |
50 Hz |
| Conductor Standard |
IS: 8130 / IEC 60228 |
| Insulation Standard |
IS: 7098 (Part I & II), IEC 60502 |
| Installation Type |
Overhead (pole-mounted or wall-supported) |
-
| Specification |
Details |
| Type |
Aluminium Compression / Crimping Type Lug |
| Application |
Used for terminating aluminium conductors in transformers, switchgear, control panels, and cable joints |
| Material |
High-conductivity aluminium (99.5% pure ETP grade) |
| Cable Compatibility |
Suitable for aluminium conductors from 10 mm² to 1000 mm² |
| Operation |
Crimped connection using standard hydraulic or mechanical tools |
| Mounting Type |
Bolt-on terminal connection |
| Temperature Range |
-20°C to +90°C (continuous) |
| Conductor Type |
Suitable for solid, stranded, or sector-shaped aluminium conductors |
| Standard Compliance |
IS 8309, BS 6121, DIN 46235, IEC 61238 |
| Finish Type |
Bright tinned or natural aluminium finish |
-
| Specification |
Details |
| Type |
Drop Out (DO) Fuse Wire / Fuse Element |
| Application |
Used in Drop Out (DO) fuse units for protecting 11 kV / 22 kV / 33 kV overhead power distribution lines and transformers |
| Material |
Tin-plated / Silver-plated Copper, Aluminum, or Special Fuse Alloy (e.g., Copper-Silver-Zinc) |
| System Voltage |
11 kV / 22 kV / 33 kV |
| Operation |
Melts under fault or overload current to isolate the faulty section |
| Mounting Type |
Fitted into DO fuse carrier / link assembly |
| Fuse Type |
Non-rewirable, high rupture capacity type |
| Standards Compliance |
IS: 9385 (Part I & II), IEC 282, and relevant Indian utility standards |
| Available Forms |
Wire form (spool), pre-cut lengths, or pre-fitted elements |
-
| Specification |
Details |
| Type |
Polymer (Polymeric Housed) Lightning Arrester |
| Application |
Used for protection of power distribution transformers, lines, and equipment from lightning and switching surges |
| System Voltage |
11 kV / 22 kV / 33 kV (3 Phase, 50 Hz) |
| Rated Voltage (Ur) |
12 kV for 11kV system; 24 kV for 22kV system; 36 kV for 33kV system |
| Nominal Discharge Current |
5 kA / 10 kA (8/20 µs waveform) |
| Mounting Type |
Pole or structure mounted (horizontal/vertical) |
| Housing Material |
Silicon rubber polymer housing (UV and weather resistant) |
| Design Type |
Gapless, metal oxide (ZnO) varistor type |
| Standard Compliance |
IEC 60099-4, IS: 3070 (Part 3) |
| Frequency |
50 Hz |
| Installation |
Outdoor installation for overhead or substation systems |