- “Gi Nut Bolt” already exists in your wishlist
-
Rod
Specification Details Type Brass Bushing Rod / Transformer Rod Assembly Application Used in oil-filled distribution and power transformers for electrical connection between winding and external terminals Material High-conductivity Electrolytic Brass (CuZn39Pb3 or equivalent) System Voltage Suitable for up to 33 kV Mounting Type Through-bushing or terminal mounting Operation Static electrical connection (non-moving part) Connection Type Threaded both ends for nut tightening and secure connection Standards Compliance IS 3347, IS 7421, IEC 60137 Finish Type Natural polished brass / Tin-plated finish -
MVt Kit
Specification Details Type MV (Medium Voltage) Tee Connector / Separable Connector Application Used to connect medium voltage (MV) cables to switchgear, transformers, RMUs, or junction boxes System Voltage 11 kV / 22 kV / 33 kV (3 Phase, 50 Hz) Connector Type Separable Tee Type (Plug-in) Connector Insulation Type EPDM / Silicone Rubber (High-Grade Elastomer) Conductor Compatibility Aluminium or Copper Conductors Mounting Type Plug-in type connection to bushing or interface (as per EN 50180 / 50181) Conductor Range 25 mm² – 400 mm² Operation Provides screened and fully insulated connection under load or energized conditions Standards Compliance IEC 60502-4, IEEE 386, CENELEC HD 629.1.S2 Design Interface Type C / Type A / Type B as per standard configuration Installation Location Indoor / Outdoor (with screened protection) -
Polymer-Lightnin G-Arrestor
Specification Details Type Polymer (Polymeric Housed) Lightning Arrester Application Used for protection of power distribution transformers, lines, and equipment from lightning and switching surges System Voltage 11 kV / 22 kV / 33 kV (3 Phase, 50 Hz) Rated Voltage (Ur) 12 kV for 11kV system; 24 kV for 22kV system; 36 kV for 33kV system Nominal Discharge Current 5 kA / 10 kA (8/20 µs waveform) Mounting Type Pole or structure mounted (horizontal/vertical) Housing Material Silicon rubber polymer housing (UV and weather resistant) Design Type Gapless, metal oxide (ZnO) varistor type Standard Compliance IEC 60099-4, IS: 3070 (Part 3) Frequency 50 Hz Installation Outdoor installation for overhead or substation systems -
Do Fuse Wires
Specification Details Type Drop Out (DO) Fuse Wire / Fuse Element Application Used in Drop Out (DO) fuse units for protecting 11 kV / 22 kV / 33 kV overhead power distribution lines and transformers Material Tin-plated / Silver-plated Copper, Aluminum, or Special Fuse Alloy (e.g., Copper-Silver-Zinc) System Voltage 11 kV / 22 kV / 33 kV Operation Melts under fault or overload current to isolate the faulty section Mounting Type Fitted into DO fuse carrier / link assembly Fuse Type Non-rewirable, high rupture capacity type Standards Compliance IS: 9385 (Part I & II), IEC 282, and relevant Indian utility standards Available Forms Wire form (spool), pre-cut lengths, or pre-fitted elements -
ABC Cable
Specification Details Type Aerial Bunched Cable (ABC) Application Used for overhead power distribution in low and medium voltage networks System Voltage LV: 1.1 kV / MV: 11 kV or 33 kV (as per configuration) Conductor Material Aluminium (Stranded, compacted, circular) Insulation Material XLPE (Cross-Linked Polyethylene) / HDPE (High-Density Polyethylene) Core Configuration 2 Core / 3 Core / 4 Core + 1 Neutral (Messenger Wire optional) Messenger Wire (Optional) Insulated or bare aluminium alloy wire for mechanical support Frequency 50 Hz Conductor Standard IS: 8130 / IEC 60228 Insulation Standard IS: 7098 (Part I & II), IEC 60502 Installation Type Overhead (pole-mounted or wall-supported) -
Gi Nut Bolt
Specification Details Type GI (Galvanized Iron) Hex Nut and Bolt Set Application Used in transmission towers, pole line hardware, substation structures, and general-purpose fastening Material Mild Steel / Carbon Steel (as per IS:1367) Surface Coating Hot Dip Galvanized (HDG) Thread Type Metric (MM) / UNC / UNF (custom options available) Operation Manual fastening using wrench or spanner Mounting Type Through-hole, clamping, or structure-mounted Head Type Hexagonal head for easy torque application Standard Compliance IS 1367, IS 3757, IS 1363, DIN 933/934 Finish Type Hot dip galvanized zinc coating (minimum 40–80 microns) -
Brass Nut bolt
Specification Details Type Brass Hex Nut and Bolt Set Application Used in electrical fittings, switchgear, transformers, busbars, and general-purpose fastening Material High-grade brass (CuZn39Pb3 / IS 319 Type I) Thread Type Metric (MM) / UNC / UNF (as per requirement) Operation Manual fastening using wrench or spanner Mounting Type Through-hole, clamp, or plate mounting Head Type Hexagonal head for easy grip and torque application Standard Compliance IS 1367, IS 319, BS 4183, DIN 933/934 Finish Type Natural brass, nickel-plated, or chrome-plated (optional) -
Back Plate
Specification Details Type Copper Back Plate / Connector Plate Application Used as a connecting terminal or mounting plate in transformers, switchgear, and electrical panels Material High conductivity electrolytic copper (Cu-ETP / Cu 99.9%) Mounting Type Bolt-on type for busbar, terminal, or bushing connections System Voltage Suitable for up to 33 kV applications (depending on insulation and system design) Operation Static mechanical and electrical connection component Compatibility Fits transformer terminals, AB switch connectors, or heavy-duty earthing setups Standards IS: 613, IS: 1897, IS: 1367, IEC 60439 Design Type Flat plate with multiple precision-drilled holes for mechanical fastening -
Ab Switch
Specification Details Type Outdoor, triple pole (3-phase), gang-operated Air Break (AB) Switch Application Used for isolating or switching high-voltage power lines and equipment under off-load conditions System Voltage 11 kV, 22 kV, or 33 kV (3-phase, 50 Hz, solidly earthed neutral system) Rated Voltage 12 kV for 11kV system; 24 kV for 22kV system; 36 kV for 33kV system Operation Manual operation through ground-level handle and GI pipe operating rod Mounting Horizontal / Vertical mounting on pole or substation structure Insulation Type Polymer / Porcelain post insulators (2 or 3 per phase) Standard Compliance IEC 62271-103, IS: 9920 (Part I to IV), IS: 2544 Design Type Tilting / Rotating gang-operated type with visible air gap -
Suspension Clamp
Specification Details Type Suspension Clamp for LV ABC System Application Used to suspend and support LV ABC (Aerial Bundled Cable) conductors on poles or walls at intermediate spans System Voltage Up to 1.1 kV (Low Voltage Overhead Distribution Lines) Cable Compatibility Suitable for 2-core, 3-core, or 4-core ABC cables (16 mm² – 95 mm²) Installation Fixed on poles with a hook, bracket, or banding; tool-free mounting design Operation Provides mechanical suspension without damaging the cable insulation Mounting Orientation Vertical or horizontal pole mounting Standards Conforms to NFC 33-040, EN 50483-3, IEC 61284, and relevant Indian Standards Design Type Flexible swivel type allowing angular movement and vibration absorption -
Piercing Connector
Specification Details Type Insulation Piercing Connector (IPC) Application Used for branching or tapping connections in LV Aerial Bundled Cable (ABC) systems without stripping insulation System Voltage Up to 1.1 kV (Low Voltage Distribution Networks) Cable Compatibility Main (Run): 16–95 mm², Tap: 16–95 mm² (as per image marking) Operation Mechanical tightening with shear-head bolt ensuring perfect contact pressure Installation Tool-operated, no stripping or pre-processing of cable insulation required Mounting Suitable for overhead ABC systems and insulated copper/aluminum conductors Standards Conforms to NFC 33-020, EN 50483-4, and IEC 61238 standards Design Type Fully insulated, weatherproof, and UV-resistant clamp body