• Anchor Dead End clamp

    Specification Details
    Type Anchor / Dead End Clamp for ABC Cable
    Application Used for terminating and anchoring LV aerial bundled cables (ABC) on poles or walls
    System Voltage Up to 1.1 kV (Low Voltage Distribution System)
    Cable Range Suitable for 2-core, 3-core, or 4-core ABC cables (16 mm² – 95 mm²)
    Operation Mechanical tension type; no special tools required for installation
    Installation Easy installation without cutting or stripping cable insulation
    Mounting Pole-mounted or wall-mounted using hooks or brackets
    Standards Conforms to NFC 33-042, IEC 61284, and relevant Indian standards
    Design Type Wedge-type self-locking design with stainless steel bail
  • Mid span joint

    Specification Details
    Type Mid Span Joint / Straight Joint Connector
    Application Used for connecting or extending LV ABC (Aerial Bundled Cable) conductors without cutting insulation
    System Voltage Up to 1.1 kV (Low Voltage Distribution System)
    Cable Compatibility Suitable for 2-core, 3-core, or 4-core LV ABC cables (16 mm² – 150 mm²)
    Operation Mechanical / shear-head bolt type; ensures reliable connection without crimping
    Installation Quick and easy – no stripping of cable insulation required
    Mounting Inline jointing of conductors at mid-span
    Standards Conforms to NFC 33-020, IEC 61238, and IS: 13779 / IS: 5561
    Design Type Insulated, waterproof, and fully sealed joint for outdoor service
  • Piercing Connector

    Specification Details
    Type Insulation Piercing Connector (IPC)
    Application Used for branching or tapping connections in LV Aerial Bundled Cable (ABC) systems without stripping insulation
    System Voltage Up to 1.1 kV (Low Voltage Distribution Networks)
    Cable Compatibility Main (Run): 16–95 mm², Tap: 16–95 mm² (as per image marking)
    Operation Mechanical tightening with shear-head bolt ensuring perfect contact pressure
    Installation Tool-operated, no stripping or pre-processing of cable insulation required
    Mounting Suitable for overhead ABC systems and insulated copper/aluminum conductors
    Standards Conforms to NFC 33-020, EN 50483-4, and IEC 61238 standards
    Design Type Fully insulated, weatherproof, and UV-resistant clamp body
  • Suspension Clamp

    Specification Details
    Type Suspension Clamp for LV ABC System
    Application Used to suspend and support LV ABC (Aerial Bundled Cable) conductors on poles or walls at intermediate spans
    System Voltage Up to 1.1 kV (Low Voltage Overhead Distribution Lines)
    Cable Compatibility Suitable for 2-core, 3-core, or 4-core ABC cables (16 mm² – 95 mm²)
    Installation Fixed on poles with a hook, bracket, or banding; tool-free mounting design
    Operation Provides mechanical suspension without damaging the cable insulation
    Mounting Orientation Vertical or horizontal pole mounting
    Standards Conforms to NFC 33-040, EN 50483-3, IEC 61284, and relevant Indian Standards
    Design Type Flexible swivel type allowing angular movement and vibration absorption
  • Ab Switch

    Specification Details
    Type Outdoor, triple pole (3-phase), gang-operated Air Break (AB) Switch
    Application Used for isolating or switching high-voltage power lines and equipment under off-load conditions
    System Voltage 11 kV, 22 kV, or 33 kV (3-phase, 50 Hz, solidly earthed neutral system)
    Rated Voltage 12 kV for 11kV system; 24 kV for 22kV system; 36 kV for 33kV system
    Operation Manual operation through ground-level handle and GI pipe operating rod
    Mounting Horizontal / Vertical mounting on pole or substation structure
    Insulation Type Polymer / Porcelain post insulators (2 or 3 per phase)
    Standard Compliance IEC 62271-103, IS: 9920 (Part I to IV), IS: 2544
    Design Type Tilting / Rotating gang-operated type with visible air gap
  • Back Plate

    Specification Details
    Type Copper Back Plate / Connector Plate
    Application Used as a connecting terminal or mounting plate in transformers, switchgear, and electrical panels
    Material High conductivity electrolytic copper (Cu-ETP / Cu 99.9%)
    Mounting Type Bolt-on type for busbar, terminal, or bushing connections
    System Voltage Suitable for up to 33 kV applications (depending on insulation and system design)
    Operation Static mechanical and electrical connection component
    Compatibility Fits transformer terminals, AB switch connectors, or heavy-duty earthing setups
    Standards IS: 613, IS: 1897, IS: 1367, IEC 60439
    Design Type Flat plate with multiple precision-drilled holes for mechanical fastening
  • Brass Nut bolt

    Specification Details
    Type Brass Hex Nut and Bolt Set
    Application Used in electrical fittings, switchgear, transformers, busbars, and general-purpose fastening
    Material High-grade brass (CuZn39Pb3 / IS 319 Type I)
    Thread Type Metric (MM) / UNC / UNF (as per requirement)
    Operation Manual fastening using wrench or spanner
    Mounting Type Through-hole, clamp, or plate mounting
    Head Type Hexagonal head for easy grip and torque application
    Standard Compliance IS 1367, IS 319, BS 4183, DIN 933/934
    Finish Type Natural brass, nickel-plated, or chrome-plated (optional)
  • Gi Nut Bolt

    Specification Details
    Type GI (Galvanized Iron) Hex Nut and Bolt Set
    Application Used in transmission towers, pole line hardware, substation structures, and general-purpose fastening
    Material Mild Steel / Carbon Steel (as per IS:1367)
    Surface Coating Hot Dip Galvanized (HDG)
    Thread Type Metric (MM) / UNC / UNF (custom options available)
    Operation Manual fastening using wrench or spanner
    Mounting Type Through-hole, clamping, or structure-mounted
    Head Type Hexagonal head for easy torque application
    Standard Compliance IS 1367, IS 3757, IS 1363, DIN 933/934
    Finish Type Hot dip galvanized zinc coating (minimum 40–80 microns)
  • ABC Cable

    Specification Details
    Type Aerial Bunched Cable (ABC)
    Application Used for overhead power distribution in low and medium voltage networks
    System Voltage LV: 1.1 kV / MV: 11 kV or 33 kV (as per configuration)
    Conductor Material Aluminium (Stranded, compacted, circular)
    Insulation Material XLPE (Cross-Linked Polyethylene) / HDPE (High-Density Polyethylene)
    Core Configuration 2 Core / 3 Core / 4 Core + 1 Neutral (Messenger Wire optional)
    Messenger Wire (Optional) Insulated or bare aluminium alloy wire for mechanical support
    Frequency 50 Hz
    Conductor Standard IS: 8130 / IEC 60228
    Insulation Standard IS: 7098 (Part I & II), IEC 60502
    Installation Type Overhead (pole-mounted or wall-supported)
  • Aluminium Lug

    Specification Details
    Type Aluminium Compression / Crimping Type Lug
    Application Used for terminating aluminium conductors in transformers, switchgear, control panels, and cable joints
    Material High-conductivity aluminium (99.5% pure ETP grade)
    Cable Compatibility Suitable for aluminium conductors from 10 mm² to 1000 mm²
    Operation Crimped connection using standard hydraulic or mechanical tools
    Mounting Type Bolt-on terminal connection
    Temperature Range -20°C to +90°C (continuous)
    Conductor Type Suitable for solid, stranded, or sector-shaped aluminium conductors
    Standard Compliance IS 8309, BS 6121, DIN 46235, IEC 61238
    Finish Type Bright tinned or natural aluminium finish
  • Do Fuse Wires

    Specification Details
    Type Drop Out (DO) Fuse Wire / Fuse Element
    Application Used in Drop Out (DO) fuse units for protecting 11 kV / 22 kV / 33 kV overhead power distribution lines and transformers
    Material Tin-plated / Silver-plated Copper, Aluminum, or Special Fuse Alloy (e.g., Copper-Silver-Zinc)
    System Voltage 11 kV / 22 kV / 33 kV
    Operation Melts under fault or overload current to isolate the faulty section
    Mounting Type Fitted into DO fuse carrier / link assembly
    Fuse Type Non-rewirable, high rupture capacity type
    Standards Compliance IS: 9385 (Part I & II), IEC 282, and relevant Indian utility standards
    Available Forms Wire form (spool), pre-cut lengths, or pre-fitted elements
  • Polymer-Lightnin G-Arrestor

    Specification Details
    Type Polymer (Polymeric Housed) Lightning Arrester
    Application Used for protection of power distribution transformers, lines, and equipment from lightning and switching surges
    System Voltage 11 kV / 22 kV / 33 kV (3 Phase, 50 Hz)
    Rated Voltage (Ur) 12 kV for 11kV system; 24 kV for 22kV system; 36 kV for 33kV system
    Nominal Discharge Current 5 kA / 10 kA (8/20 µs waveform)
    Mounting Type Pole or structure mounted (horizontal/vertical)
    Housing Material Silicon rubber polymer housing (UV and weather resistant)
    Design Type Gapless, metal oxide (ZnO) varistor type
    Standard Compliance IEC 60099-4, IS: 3070 (Part 3)
    Frequency 50 Hz
    Installation Outdoor installation for overhead or substation systems

Main Menu